A natural disaster brought a major production facility to a standstill.
When a devastating tornado ripped through Nestlé Waters’ (Nestlé) bottling facility in Hawkins, Texas, production came to an abrupt standstill. The roof and interior walls were badly damaged, as well as the rooftop mechanical units and exterior lights. Nestlé called on Haskell, which originally built the 403,000-square-foot facility, to help get operations back up and running.
Before the storm, this facility was a design-build success for Haskell and Nestlé Waters.
Haskell was initially contracted by Nestlé years earlier to construct this greenfield, spring-fed water bottling and distribution facility for the company’s Ozarka Spring brand. The scope included five miles of spring water line piping, seven borehole buildings and an immediate pumping station. Through the time savings afforded by the design-build delivery model, we were able to achieve joint occupancy in just 4.5 months, finishing ahead of schedule and under budget. The facility also met the criteria for Silver LEED certification.
We helped get Nestlé back up and running in record time.
Nestlé faced mounting revenue losses when the tornado rendered its seven bottling production lines inoperable. Haskell arrived with urgency and began repairs that included new structural steel, metal siding, roofing, dock doors and replacement HVAC equipment. Through expert scheduling and execution, our team had the facility back in full production within 49 days of the disaster. While on site, Haskell also provided additional services to upgrade the facility’s drainage.
Sustainability by Design
- LEED® Silver Certification
Related Topics
Talk to a Subject Matter Expert
Project Highlights
403,000 SF
Spring-fed water bottling process facility with an integral distribution center
Original scope was for a design-build, greenfield facility that included five miles of spring water line piping, seven borehole buildings and an intermediate pumping station
Facility was awarded Silver LEED® Certification
Joint occupancy was reached in 4.5 months and the entire project was completed in 9 months, ahead of schedule and under budget
Several years after completion, the facility was badly damaged in a tornado, Haskell was contracted to provide critical repairs
Work included replacing the damaged roof, the CMU interior walls, the rooftop mechanical units, and the exterior lights in the facility
While these repairs were underway, Nestlé also asked Haskell to upgrade the drainage system on the facility
Related Projects
Malaysia
Bio-Conversion Facility Plant
Confidential Location
Confidential Plant-Based Protein Production Facility
Northlake, Texas
Farmer Brothers EPC Coffee Manufacturing
Related News & Insights
How Haskell, VIKTOR Partner for Agentic Structural Design Assistance
Learn the results of testing that coordinated validated engineering apps, reducing manual data transfers and preserving engineer review.
Kevin Crump will Bring a Student Focus to Foundation Chair Role
Meet Haskell's Director of Design and Technology Innovation and learn how he will advance scholarships and education programs for future engineers.
Shaping Outcomes in an Uncertain Construction Environment
See how CM/GC delivery brings cost visibility into design. Learn how early collaboration helps align scope, budget and schedule.
Planning a Functional Beverage Line for What Comes Next
From cold-chain needs to supplier risk, functional beverages require decisions beyond formulation. Learn how to create an adaptable facility.










